EasyManuals Logo

Monarch NICE 5000 User Manual

Monarch NICE 5000
233 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #177 background imageLoading...
Page #177 background image
NICE5000 User Manual 7 Description of Function Codes
- 175 -
Bit Function Description
Bit0
Overload
protection
When the motor load or controller load exceeds a certain threshold,
the system performs protection and reports the motor overload or
controller overload fault.
Bit1
Output phase
loss protection
After detecting phase loss on the output side, the system performs
protection and reports the fault.
Bit3
Input phase loss
protection
After detecting phase loss on the input side, the system performs
protection and reports the fault.
Function Code Parameter Name Setting Range Default Unit Property
FA-10 Overload protection coefcient 0.50–10.00 1.00 -
After detecting that the output current exceeds (FC-10 x Rated motor current) and the
duration lasts the time specied in the inverse time lag curve, the system outputs fault Err11
indicating motor overload.
Function Code Parameter Name Setting Range Default Unit Property
FA-11
Overload pre-warning coefcient 50–100
80 %
After detecting that the output current exceeds (FA-11 x Rated motor current) and the
duration lasts the time specied in the inverse time lag curve, the system outputs a pre-
warning signal.
Function Code Parameter Name Setting Range Default Unit Property
FA-15 Program control selection 0–65535 0 -
It is used to select the elevator functions.
Each bit of the function code denes a function, as described in the following table.
If a bit is set to 1, the function indicated by this bit is enabled; if this bit is set to 0, the
function is disabled.
The functions dened by the binary bits are described in the following table.
Bit Function Description Default
Bit0
Super short oor
function
The controller cannot perform shaft auto-tuning if the oor
height is less than 500 mm. After this function is enabled, shaft
auto-tuning can be performed normally.
0
Bit1
Up slow-down
not reset for
super short oor
If this function is enabled, the up slow-down 1 signal does not
reset oor display. The down slow-down 1 signal still resets
oor display. This is valid only when the super short oor
function is enabled.
0
Bit2
Down slow-down
not reset for
super short oor
If this function is enabled, the down slow-down 1 signal does
not reset oor display. The up slow-down 1 signal still resets
oor display. This is valid only when the super short oor
function is enabled.
0