NICE5000 User Manual 7 Description of Function Codes
- 143 -
Group F5: Terminal Function Parameters
Function Code Parameter Name Setting Range Default Unit Property
F5-00
Load cell input selection 0–3
2 - ★
It is used to set the channel of setting the elevator load cell signal. When a load cell device
is used, set this parameter correctly rst.
The values are as follows:
•
0: Invalid
•
1: CTB digital input
•
2: CTB analog input
•
3: MCB analog input
Function Code Parameter Name Setting Range Default Unit Property
F5-01 X1 function selection
0–127
101 - ★
F5-02 X2 function selection 102 - ★
F5-03 X3 function selection 116 - ★
F5-04 X4 function selection 117 - ★
F5-05 X5 function selection 118 - ★
F5-06 X6 function selection 119 - ★
F5-07 X7 function selection 0 - ★
F5-08 X8 function selection 0 - ★
F5-09 X9 function selection 4 - ★
F5-10 X10 function selection 5 - ★
F5-11 X11 function selection 106 - ★
F5-12 X12 function selection 107 - ★
F5-13 X13 function selection 108 - ★
F5-14 X14 function selection 9 - ★
F5-15 X15 function selection 10 - ★
F5-16 X16 function selection 112 - ★
F5-17 X17 function selection 113 - ★
... ..
F5-28 X28 function selection 0 - ★
These parameters are used to set the functions of input terminals X1 to X24.