NICE5000 User Manual 7 Description of Function Codes
- 177 -
Bit Function Setting Bit Function Setting
Bit10
Door open by
button
1
Corresponding door
open
Bit11
Door close
by button
1
Corresponding door
open
0
Both doors open
0
Both doors open
Bit6
Front/
Back door
switchover by
switch
1
Valid
Bit13
Door mutual
exclusive
1
Only one door open
on any condition
0
Invalid
0
Both doors open
Bit14
Light curtain
judgment
1
Independent for
front door and back
door
0
Consistent for front
door and back door
Function Code Parameter Name Setting Range Default Unit Property
Fb-02
Service oors 1 of door machine 1 0–65535
65535 - ☆
Fb-03
Service oors 2 of door machine 1 0–65535
65535 - ☆
Fb-04
Service oors 3 of door machine 1 0–65535
65535 - ☆
Fb-05
Service oors 4 of door machine 1 0–65535
65535 - ☆
Fb-06
Service oors 1 of door machine 2 0–65535
65535 - ☆
Fb-07
Service oors 2 of door machine 2 0–65535
65535 - ☆
Fb-08
Service oors 3 of door machine 2 0–65535
65535 - ☆
Fb-09
Service oors 4 of door machine 2 0–65535
65535 - ☆
These parameters are used to set the service oors of door machine 1 and door machine 2.
•
Service oors 1: oors 1–16
•
Service oors 2: oors 17–32
•
Service oors 3: oors 33–48
•
Service oors 4: oors 49–56
The setting method is the same as that for F6-05.
Function Code Parameter Name Setting Range Default Unit Property
Fb-10 Door open protection time 5–99 10 s ☆
It is used to set the door open protection time.
After outputting the door open command, if the system does not receive the door open limit
signal after the time set in this parameter, the system re-opens the door. When the door
open/close times reach the value set in Fb-13, the system reports fault Err48.