EasyManuals Logo

Moog Infinity User Manual

Moog Infinity
113 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #48 background imageLoading...
Page #48 background image
© Copyright 2020 Moog, Inc.
41
Recommended separation distances between portable and mobile
RF communications equipment and the Innity pump
The Innity pump is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The
customer or the user of the Innity pump can help prevent electromagnetic interference by maintaining a minimum distance between
portable and mobile RF communications equipment (transmitters) and the Innity pump as recommended below, according to the
maximum output power of the communications equipment.
Rated maximum output
power of transmitter
W
Separation distance according to frequency of transmitter
m
150 kHz to 80 MHz
d=1.2√P
80 MHz to 800 MHz
d=1.2√P
800 MHz to 2.7 GHz
d=2.3√P
0.01 0.12 0.12 0.23
0.1 0.38 0.38 0.73
1 1.2 1.2 2.3
10 3.8 3.8 7.3
100 12 12 23
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in metres (m) can be
estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the
transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is aected by absorption and reection from
structures, objects and people.
Routine Maintenance
There is no routine calibration or adjustment procedure required for
Innity.
There are no user-serviceable parts. All service requests
should be referred to Moog technical service.
Disposal Information
At the end of their service lifetime, the pump and its electrical accessories (AC Adapter
Charger and Data Download Accessory Cable) should be disposed of according to
local standards and regulations governing the disposal of electronic waste (e-waste).
Other accessories can be disposed of or recycled as standard non-hazardous waste.
Start Up Graph and Trumpet Graph
Available upon request
9. ADDITIONAL TECHNICAL INFORMATION

Table of Contents

Other manuals for Moog Infinity

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Moog Infinity and is the answer not in the manual?

Moog Infinity Specifications

General IconGeneral
ModelInfinity
TypeInfusion Pump
Occlusion Pressure SettingsLow, Medium, High
AlarmsOcclusion, Low battery
Operating Temperature10°C to 40°C
Storage Temperature-20°C to 60°C
ManufacturerMoog
Infusion ModesContinuous, Intermittent
DisplayLCD
CompatibilityStandard infusion sets

Related product manuals