9 - 62 DS4208 Digital Scanner Product Reference Guide
Inverse 1D
Parameter # F1h 4Ah
This parameter sets the 1D inverse decoder setting. Options are:
Regular Only - the digital scanner decodes regular 1D bar codes only.
Inverse Only - the digital scanner decodes inverse 1D bar codes only.
Inverse Autodetect - the digital scanner decodes both regular and inverse 1D bar codes.
*Regular
(00h)
Inverse Only
(01h)
Inverse Autodetect
(02h)

Table of Contents

Other manuals for Motorola DS4208

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motorola DS4208 and is the answer not in the manual?

Motorola DS4208 Specifications

General IconGeneral
ConnectivityWired
SealingIP43
Voltage5 VDC ± 10%
Scan PatternOmnidirectional
InterfaceUSB, RS232, Keyboard Wedge
Decode Capability1D
Drop SpecificationWithstands multiple 6 ft. (1.8 m) drops to concrete
Operating Temperature32° to 104° F (0° to 40° C)
Storage Temperature-40°F to 158°F (-40°C to 70°C)
Humidity5% to 95% (non-condensing)
LightingTolerant to typical artificial indoor and natural outdoor (direct sunlight) lighting conditions
Power Consumption2.5 W (typical)
Current500 mA
Cable Length6 ft (1.8 m)