Chapter 3 Maintenance, Troubleshooting &
Technical Specifications
Introduction
This chapter provides suggested digital scanner maintenance, troubleshooting, technical specifications, and signal
descriptions (pinouts).
Maintenance
General Scanner Maintenance
Cleaning the scan window is required. A dirty window can affect scanning accuracy.
Do not allow abrasive material to touch the window.
Remove any dirt particles with a damp cloth.
Wipe the window using a tissue moistened with approved cleanser (listed below).
Do not spray water or other cleaning liquids directly into the window.
In addition to the cleaning requirements above, healthcare configurations of the scanner (DS4208-HC) may require
additional maintenance.
Healthcare Scanner Maintenance
The DS4208-HC design allows safe cleansing of the product plastics with a variety of cleaning products and
disinfectants. If required, wipe the digital scanner with the following list of approved cleansers:
Isopropyl alcohol
Bleach/sodium hypochlorite
Hydrogen peroxide
Gentle dish soap and water
IMPORTANT Cleansers that contain active ingredients not listed above should not be utilized on the
DS4208-HC digital scanner.

Table of Contents

Other manuals for Motorola DS4208

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motorola DS4208 and is the answer not in the manual?

Motorola DS4208 Specifications

General IconGeneral
ConnectivityWired
SealingIP43
Voltage5 VDC ± 10%
Scan PatternOmnidirectional
InterfaceUSB, RS232, Keyboard Wedge
Decode Capability1D
Drop SpecificationWithstands multiple 6 ft. (1.8 m) drops to concrete
Operating Temperature32° to 104° F (0° to 40° C)
Storage Temperature-40°F to 158°F (-40°C to 70°C)
Humidity5% to 95% (non-condensing)
LightingTolerant to typical artificial indoor and natural outdoor (direct sunlight) lighting conditions
Power Consumption2.5 W (typical)
Current500 mA
Cable Length6 ft (1.8 m)