Decode Session Timeout
Parameter # 88h
This parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in
0.1 second increments from 0.5 to 9.9 seconds. The default timeout is 9.9 seconds.
To set a Decode Session Timeout, scan the bar code below. Next, scan two numeric bar codes from Appendix D,
Numeric Bar Codes that correspond to the desired on time. Enter a leading zero for single digit numbers. For
example, to set a Decode Session Timeout of 0.5 seconds, scan the bar code below, then scan the 0 and 5 bar
codes. To correct an error or change the selection, scan Cancel on page D-2.
Timeout Between Decodes, Same Symbol
Parameter # 89h
Use this option in presentation mode or Continuous Bar Code Read to prevent the beeper from continuously
beeping when a symbol is left in the digital scanner’s field of view. It is programmable in 0.1 second increments
from 0.0 to 9.9 seconds. The default interval is 0.5 seconds.
To select the timeout between decodes for the same symbol, scan the bar code below, then scan two numeric bar
codes from Appendix D, Numeric Bar Codes that correspond to the desired interval, in 0.1 second increments.
NOTE Decode Session Timeout cannot be less than or equal to either Timeout Between Decodes, Same Symbol
or Timeout Between Decodes, Different Symbols.
Decode Session Timeout
NOTE Timeout Between Decodes, Same Symbol cannot be greater than or equal to the Decode Session
Timeout.
Timeout Between Decodes, Same Symbol

Table of Contents

Other manuals for Motorola DS4208

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motorola DS4208 and is the answer not in the manual?

Motorola DS4208 Specifications

General IconGeneral
ConnectivityWired
SealingIP43
Voltage5 VDC ± 10%
Scan PatternOmnidirectional
InterfaceUSB, RS232, Keyboard Wedge
Decode Capability1D
Drop SpecificationWithstands multiple 6 ft. (1.8 m) drops to concrete
Operating Temperature32° to 104° F (0° to 40° C)
Storage Temperature-40°F to 158°F (-40°C to 70°C)
Humidity5% to 95% (non-condensing)
LightingTolerant to typical artificial indoor and natural outdoor (direct sunlight) lighting conditions
Power Consumption2.5 W (typical)
Current500 mA
Cable Length6 ft (1.8 m)