EasyManuals Logo

Motorola DS4208 Product Reference Guide

Motorola DS4208
364 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #252 background imageLoading...
Page #252 background image
9 - 80 DS4208 Digital Scanner Product Reference Guide
Data Matrix
Parameter # F0h 24h
To enable or disable Data Matrix, scan the appropriate bar code below.
Data Matrix Inverse
Parameter # F1h 4Ch
This parameter sets the Data Matrix inverse decoder setting. Options are:
Regular Only - the digital scanner decodes regular Data Matrix bar codes only.
Inverse Only - the digital scanner decodes inverse Data Matrix bar codes only.
Inverse Autodetect - the digital scanner decodes both regular and inverse Data Matrix bar codes.
*Enable Data Matrix
(01h)
Disable Data Matrix
(00h)
NOTE Inverse Autodetect is the default for the healthcare configuration (DS4208-HC) of the DS4208 digital
scanner.
*Regular
(00h)
Inverse Only
(01h)
Inverse Autodetect
(02h)

Table of Contents

Other manuals for Motorola DS4208

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motorola DS4208 and is the answer not in the manual?

Motorola DS4208 Specifications

General IconGeneral
ConnectivityWired
SealingIP43
Voltage5 VDC ± 10%
Scan PatternOmnidirectional
InterfaceUSB, RS232, Keyboard Wedge
Decode Capability1D
Drop SpecificationWithstands multiple 6 ft. (1.8 m) drops to concrete
Operating Temperature32° to 104° F (0° to 40° C)
Storage Temperature-40°F to 158°F (-40°C to 70°C)
Humidity5% to 95% (non-condensing)
LightingTolerant to typical artificial indoor and natural outdoor (direct sunlight) lighting conditions
Power Consumption2.5 W (typical)
Current500 mA
Cable Length6 ft (1.8 m)

Related product manuals