VOC Site Lock Time (sec) Enter the desired value directly or use the UP/DOWN arrow keys to
scroll through the available choices. This field defines the maximum
time that a radio will remain locked onto a Voice-on-Control Site
before it will attempt to lock on to another site (and possibly enter an
out-of-range state). Valid entries range from 15 to 255 seconds in one-
second increments.
The default is 15 seconds.
VOC Pended Emer Time (ms) Use the UP/DOWN arrow keys to select a value for this timer or enter
a value directly. This is the maximum length of time that the radio will
delay before a certain subset of ISWs will be sent while the radio is in
VOC mode. Valid entries range from 500 to 6000 ms in 25-ms
increments.
Note: Most ISWs are not permitted to be sent in while the radio
is in VOC mode (the exceptions being Emergency and Phone
Reject requests).
The default is 500 ms.
VOC Activation Time (ms) Use the UP/DOWN arrow keys to select a value for this timer or enter
a value directly. This field determines the maximum length of time
that the radio will delay before sending in ISW requests upon receiving
a system status OSW indicating the site is exiting VOC Mode. The
valid range is 500 ms to 6000 ms in 25-ms increments.
The default is 20.

Table of Contents

Other manuals for Motorola MCS 2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motorola MCS 2000 and is the answer not in the manual?

Motorola MCS 2000 Specifications

General IconGeneral
BrandMotorola
ModelMCS 2000
CategoryRadio
LanguageEnglish

Related product manuals