83
Side Button
Configuration
(HT 1000 “A”
Revision Models only)
From the MAIN MENU, press F4 and then F3 twice to access this
screen.
This screen allows you to modify the side button configuration for HT
1000 “A” revision models only.
Function Key Descriptions
F5 - PRINT Prints the current system configuration.
F9 - DEFAULT Resets the fields on this screen to their default values.
Field Definitions
Permanent Monitor Use the UP/DOWN arrow keys to enable/disable this feature. If this
option is enabled, the Permanent Monitor feature will be enabled in
the radio. In order to enter Permanent Monitor, the radio user will
have to hold down the radio’s Monitor button for the time period
specified in the Monitor Long Press Period field on this screen. The
type of operation of Permanent Monitor will be determined by the
setting in the Permanent Monitor Definition field. The Permanent
Monitor state is not preserved across channel changes or power cycling.
The default is Enabled.
Monitor Long Press Period (sec) This field will be visible only if the Permanent Monitor feature on this screen
is enabled. Enter a value directly or use the UP/DOWN arrow keys to
select the time period for which the user must hold down the Monitor
button in order to engage Permanent Monitor mode. The valid range
is one to 16 seconds in one-second increments.
The default is 5 seconds.
DCC
MOTOROLA Radio Service Software Use <: keys to adjust value.
HT/JT1000/VISAR Model : H01SDC9AA3AN Use <Enter> key to go to next feature
Serial:
CHANGE:RADIO:SIDE BUTTON
Side Button Configuration
-------------------------
Permanent Monitor (SB3).................................... Enabled
Monitor Long Press Period (sec).................................5
Permanent Monitor Definition...........................Open Squelch
External Mandown Switch.................................... Enabled
F1 F2 F3 F4 F5 F6 F7 F8 F9 F10
HELP PRINT DEFAULT EXIT