SNMP Read/Write Settings
SNMP Versions
Setting
Description
V1, V2c, V3, or
V1, V2c, or
V3 only
Specifies the SNMP protocol version used to manage the
switch.
V1, V2c
V1, V2c Read Community
Setting
Description
Max. 30 characters
Specifies the community string to authenticate the SNMP
agent for read-only access. The SNMP agent will access all
objects with read-only permissions using this community
string.
Public
V1, V2c Write/Read Community
Setting
Description
Max. 30 characters
Specifies the community string to authenticate the SNMP
agent for read/write access. The SNMP server will access all
objects with read/write permissions using this community
string.
Private
For SNMP V3, two levels of privilege are available f or accessing the Moxa switch. Admin privilege provides
access and authorization to read and write the MIB f ile. User privilege only allows reading the MIB f ile.
Admin Auth. Type (for SNMP V1, V2c, V3, and V3 only)
Setting
Description
No-Auth
Allows the admin account to access objects without
authentication.
No
MD5-
Auth
Authentication will be based on the HMAC-MD5 algorithms. 8-
character passwords are the minimum requirement for
authentication.
No
SHA-
Auth
Authentication will be based on the HMAC-SHA algorithms. 8-
character passwords are the minimum requirement for
authentication.
No
Enable Admin Data Encryption Key (for SNMP V1, V2c, V3, and V3 only)
Setting
Description
Enable
Enables data encryption (via the DES algorithm) using the
specified data encryption key (between 8 and 30 characters).
No
Disable
Specif ies that data will not be encrypted.
User Auth. Type (for SNMP V1, V2c, V3 and V3 only)
Setting
Description
No-Auth
Allows the admin account and user account to access objects
without authentication.
No
MD5-Auth
Authentication will be based on the HMAC-MD5 algorithms. 8-
character passwords are the minimum requirement for
authentication.
No
SHA-Auth
Authentication will be based on the HMAC-SHA algorithms. 8-
character passwords are the minimum requirement for
authentication.
No
Enable User Data Encryption Key (for SNMP V1, V2c, V3 and V3 only)
Setting
Description
Enable
Enables data encryption using the specified data encryption
key (between 8 and 30 characters).
No
Disable
No data encryption

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Moxa Technologies IKS-G6524A and is the answer not in the manual?

Moxa Technologies IKS-G6524A Specifications

General IconGeneral
BrandMoxa Technologies
ModelIKS-G6524A
CategorySwitch
LanguageEnglish

Related product manuals