Moxa Managed Ethernet Switch/Extender Featured Functions
3-16
Preferred Master
Setting Description Factory Default
True or False Set this switch to be the Grand Master. False
priority1
Setting Description Factory Default
0 to 255 Set first priority value; 0 = highest priority, 255 = lowest
priority.
128
priority2
Setting Description Factory Default
0 to 255 Set second priority value; 0 = highest priority, 255 = lowest
128
clockClass
Setting Description Factory Default
0 to 255 The clockClass attribute denotes the traceability of the time or
frequency distributed by the grandmaster clock.
248
clockAccuracy
Setting Description Factory Default
0x21 The clockAccuracy
best master clock (BMC) algorithm. This value is fixed at 0x21,
which means the time of the EDS switch is accurate to within
0x21
Timescale
Setting Description Factory Default
PTP or ARB PTP timescale: In normal operation, the epoch is the PTP
epoch and the timescale is continuous. The time unit is SI
seconds, as realized on the rotating geoid (SI: International
System).
administrative procedure. The epoch can be reset during
normal operation. Between invocations of the
administrative procedure, the timescale is continuous.
Additional invocations of the administrative procedure may
introduce discontinuities in the overall timescale.
PTP
ARB Time
Setting Description Factory Default
0 to 255 The geoid of the PTP clock reference time (seconds). 0
Leap59
Setting Description Factory Default
True or False
the epoch is not PTP, the value will be set to FALSE.
False
Leap61
Setting Description Factory Default
True or False
the epoch is not PTP, the value will be set to FALSE.
False
UTC Offset Valid
Setting
Factory Default
True or False The initialization value will be TRUE if the value of the current
UTC offset is known to be correct; otherwise, it will be FALSE.
False

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Moxa Technologies Managed Ethernet Switch/Extender and is the answer not in the manual?

Moxa Technologies Managed Ethernet Switch/Extender Specifications

General IconGeneral
BrandMoxa Technologies
ModelManaged Ethernet Switch/Extender
CategoryNetwork Router
LanguageEnglish

Related product manuals