Configuring the job computer
Entering field sprayer parameters
Wheel pulses
Number of pulses the wheel sensor sends to the job computer on a 100m distance. Used to calculate
the speed.
The number is determined by the wheel sensor calibration.
Regulation factor
In Automatic mode, the spray pressure will be adapted to the current speed of the field sprayer. The
adjustment should ensure that the volume of spray liquid that is applied is exactly what you defined in
the target rate. The regulation factor plays a decisive role here.
The regulation factor adjusts the reaction speed of the regulation:
▪ The higher the regulation factor, the faster the spray pressure is adjusted.
▪ The lower the regulation factor, the more slowly the spray pressure is adjusted.
When setting the regulation factor, you can pay attention to the following:
▪ If, during movement at constant speed, the current application volume jumps around the target
value, you need to reduce the regulation factor.
▪ If, when speed is changing, the application volume does not adjust to the rate quickly enough,
you need to increase the regulation factor.
Set limit values for the spray pressure
This includes the following parameters:
▪ Maximum pressure
▪ Minimum pressure
This setting defines a spray pressure range within which the spray pressure is optimal.
If the spray pressure is above or below the maximum limit values, an alarm will be triggered.
You can choose your own limit values as required.
If no pressure sensor is installed on your sprayer, you must enter "0" as the value.
Sprayer off below
If the field sprayer falls below the minimum working speed, the following happens:
▪ Application will be switched off automatically.
▪ The work screen displays the icon:
When the value is set to 0, this function is deactivated.
Regulation off below
If the field sprayer falls below this speed, the following happens:
▪ The flow will no longer be regulated and the flow remains unchanged.
▪ Manual mode will be activated.
▪ The work screen displays the icon:
When the value is set to 0, this function is deactivated.
This parameter must be higher or the same as the "Sprayer off below" parameter.