Troubleshooting
Alarm messages
Alarm appears when the “Tractor-ECU” job computer sends a signal that the mode was
switched from driving on the road to driving on the field.
When driving on the road, the joystick buttons will be ignored.
Appears when a maximum speed that was defined for unlocked axles has been exceeded.
The speed is defined by the implement manufacturer.
Lock the axle.
The implement is being operated
using an external device! To cancel,
quit this alarm.
The field sprayer is currently not being operated using the terminal, rather via an external
input device. To terminate the external operation, acknowledge the alarm. You will then be
able to operate the controls again.
Spray regulation
SPRAY REGULATION
Set rate out of reach.
The system cannot adjust the application rate to the rate.
SPRAY REGULATION
The pressure is too low
The minimum spray pressure could not be reached. Parameter: Min. pressure
SPRAY REGULATION
The pressure is too high.
Pressure is higher than defined in the parameter. Parameter: Max. pressure
L/min too high, above flow meter
specifications.
Flow is too high. The flow meter is not capable of measuring reliably.
L/min too low, below flow meter
specifications.
Flow is too low. The flow meter is not capable of measuring reliably.
System
To change the parameter, the
password must first be entered.
The function that you want to perform is only available after entering the password.
TRAIL-Control
Defective drawbar angle sensor.
The analog input voltage is outside of the valid range.
Valid range: 0.5 V to 4.5 V
1. Replace the angle sensor.
The analog input voltage is outside of the valid range. Valid range: 0.5 V to 4.5 V
1. Replace the slope sensor.