SCHEDULE TYPE:
PROJECT:
ENGINEER:
CONTRACTOR:
Nailor Industries Inc. reserves the right to change any information concerning product or pricing without notice.
15"
(381)
6 3/4"
(171)
FAN
MULTI-POINT
FLOW
SENSOR
PW
W3
+
11 1/2"
(292)
DIA. =
NOM. –
1/8" (3)
DW
DH
B
1"
(25)
W
W3
L
5 3/4"
(146)
5 3/4"
(146)
IH + 2" (51)
TL
IW + 2" (51)
12"
(305)
PH
14" (356)
TW
L
C
L
C
L
C
INDUCED
AIR
W2
W1
W2
2
W3
2
A
PRIMARY
AIR INLET
OUTSIDE
AIR INLET
IH
LEFT-HAND
PRIMARY AIR
VALVE CONTROL
ENCLOSURE
OPTIONAL
INDUCED AIR
INLET FILTER
'Q' OPTION INDUCED
AIR ATTENUATOR
10"
(254)
14" (356)
8" (203)
IW
RIGHT-HAND
PRIMARY AIR
VALVE CONTROL
ENCLOSURE
H -
1" (25)
H
HINGED FAN
CONTROLS
ENCLOSURE
OPTIONAL
90° FN2 HINGED
FAN CONTROLS
ENCLOSURE
5 1/2"
(140)
DATE B SERIES SUPERSEDES DRAWING NO.
2 - 6 - 23 3500 11 - 15 - 22 35S-OAI-1
FAN POWERED TERMINAL UNIT WITH
OUTSIDE AIR INLET EPIC ECM MOTOR
SERIES FLOW • CONSTANT OR VARIABLE VOLUME
MODELS: 35S-OAI, 35SW-OAI AND 35SE-OAI
UNIT SIZES 2 – 6
Model 35S-OAI • Basic Unit
Dimensional Data
Unit
Size
Inlet
Size
Outside
Inlet Size
W H L B
Induced Air Inlet
Outlet
Discharge
DW x DH
Filter Size
Side (std.)
IW x IH
Top (opt.)
TL x TW
Side Inlet
(std.)
Top Inlet
(opt.)
2
6, 8
(152, 203)
4, 5, 6
(102, 127, 152)
18
(457)
14
(356)
51 1/2
(1308)
6
(152)
8 x 10
(203 x 254)
10 x 14
(254 x 356)
9 1/4 x 10 1/2
(235 x 267)
10 x 12
(254 x 305)
14 x 16
(356 x 406)
3
6, 8, 10
(152, 203, 254)
4, 5, 6
(102, 127, 152)
18
(457)
18
(457)
51 1/2
(1308)
3 1/2
(89)
12 x 14
(305 x 356)
14 x 14
(356 x 356)
9 1/4 x 10 1/2
(235 x 267)
14 x 16
(356 x 406)
16 x 16
(406 x 406)
4
8, 10, 12**
(203, 254, 305)
6, 7, 8
(152, 178, 203)
26
(660)
18
(457)
56 1/2
(1435)
6
(152)
14 x 14
(356 x 356)
12 x 22
(305 x 559)
12 x 10 1/2
(305 x 267)
16 x 16
(406 x 406)
16 x 25
(406 x 635)
5
10, 12**, 14**
(254, 305, 356)
6, 7, 8
(152, 178, 203)
26
(660)
18
(457)
56 1/2
(1435)
5
(127)
14 x 14
(356 x 356)
12 x 22
(305 x 559)
13 1/4 x 11 1/2
(337 x 292)
16 x 16
(406 x 406)
16 x 25
(406 x 635)
6
10, 12**, 14**
(254, 305, 356)
6, 7, 8
(152, 178, 203)
30
(762)
19
(483)
59 1/2
(1511)
6
(152)
16 x 15
(406 x 381)
14 x 26
(356 x 660)
13 1/4 x 11 1/2
(337 x 292)
17 x 18
(432 x 457)
18 x 28
(457 x 711)
Size W1 or W2
4, 5, 6 12 (305)
7, 8 14 (356)
10 16 (406)
12** 19 (483)
14** 20 (508)
**
Flat oval inlets
W3 = W1 + W2
A =
W1 + W2
2
Electrical Data
Unit
Size
EPIC ECM Motor FLA
Motor HP 120V 208V 240V 277V
2
*
4.0 2.7 2.6 2.6
3
*
5.0 3.4 3.3 3.3
4
*
6.9 4.6 4.5 4.2
5
*
9.0 6.1 5.8 5.6
6
*
11.9 7.3 7.3 7.2
*
The ECM is a variable horsepower motor. Refer to
Selectworks schedule for actual power consumption.
FLA =
Full load amperage. All motors are single
phase/60 Hz.
DESCRIPTION:
18 ga. (1.31) galvanized steel
channel frame with 20 ga. (1.00)
casing components.
16 ga. (1.61) galvanized steel
inclined opposed blade dampers.
45° rotation. RH CW to close. LH
CCW to close.
Separate outside ventilation air
inlet.
Ultra-high efficiency ECM
fan motor. EPIC fan volume
controller.
Multi-point averaging Diamond
Flow sensor. Supplied with
balancing tees.
Universal access panels on all
4 sides.
3/4" (19) dual density
insulation, coated to prevent
air erosion, meets requirements
of NFPA 90A and UL 181.
Single point electrical and/or
pneumatic main air connection.
Discharge opening for flanged
duct connection.
Full enclosure for factory
mounted DDC and analog
electronic controls.
Choice of right or left-hand
primary inlet location. Hand of
unit is determined by location of
primary inlet looking in direction
of airflow. Right-hand illustrated.
OPTIONS:
Digital Controls:
q Factory mounted
(supplied by others)
q Field mounted
(supplied by others)
Liner:
q Fiber-free
q Steri-liner
q Steri-liner + Perforated metal
q Perforated metal
q Solid metal
q 1" (25) fiberglass
Other:
q Left-hand controls location
q Left-hand primary inlet location
q Toggle disconnect switch
q Fan unit fusing
q 24/24V Isolation transformer
q Cross Flow Sensor (not on
primary inlet)
q 'Q' Option – Induced
Air Inlet Attenuator. (not
available w/FN2 option).
q Top entry induced air inlet
q 1" (25) Throwaway filter
q 2" (51) MERV 8 filter
q Hanger brackets.
q 1/4-turn fasteners (access
panel)
q FN2 90° Line Voltage
Enclosure
Primary/Inlet Dimensions
Oval Inlet Dimensions
Size PW x PH
12** 12 13/16 x 9 13/16 (325 x 249)
14** 16 1/16 x 9 13/16 (408 x 249)
Listed
q
FN3 Remote Line Voltage Controls
Enclosure. (See submittal FN3)
q Dust tight enclosure seal
q Remote user disconnect
Seismic Certification:
q Seismic Source International
(Standard)
q HCAI (formerly OSHPD, California)
q Special Features: _________ .
Page 1 of 2. For heat options; see page 2.