145
6-1. Configuration of High-level Instructions
Notes:
• There is no need to program the same triggers
many times when two or more high-level
instructions are programmed consecutively with
the same trigger.
In the program example shown right, the X0 for
second and third instructions can be omitted.
• Program a DF instruction when the instruction
should be executed once at the leading edge of
the trigger.
ST
X-WX
ST
X-WX
0 WRT
FN/P
FL
ENT1
OR
R-WR
NOT
DT/Ld
0 WRT
ENT0
0
X0
Trigger
F1 DMV, WR0 , DT0
S
D
Address
Operand
Destination: Destination data area (memory)
Source: Source data area
(16-bit equivalent constant or data area)
Boolean
Instruction number (function number)
Screen of NPST-GR Software in Boolean ladder mode Key operation of FP Programmer II
X0
F0 MV, DT0, DT1
X0
X0
X0
F0 MV, K0, DT0
The triggers indicated by dotted lines
are not required.
F1 DMV, DT2, DT4
F0 MV, DT6, DT7
(DF) 1
1