EasyManua.ls Logo

NCR 7167 - Page 180

NCR 7167
344 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7167 Owner’s Manual Chapter 6: Commands
November 2003
167
Type ID (n=4)
Bit Off/On Hex Decimal Function
0 Off 00 0 No logo definition loaded by application.
On 01 1 Logo loaded by application.
1 - - - Undefined
2 - - - Undefined
3 - - - Undefined
4 Off 00 0 Not used. Fixed to Off.
5 - - - Undefined
6 - - - Undefined
7 Off 00 0 Not used. Fixed to Off.
Example:
MSComm1.Output = Chr$(&H1D) & Chr$(&H49) & Chr$(n)
Transmit Printer ID, Remote Diagnostics Extension
ASCII: GS I @ n
Hexadecimal: 1D 49 40 n
Decimal:
29 73 64 n
Values of n:
Refer to table above
Range of n:
32 – 255
(not all defined but reserved)
Performs the remote diagnostic function specified by n.
Eighteen remote diagnostic items are defined: eight printer ID items and ten printer tally
items. A group of four remote diagnostic functions is assigned to each diagnostic item.
Most of the diagnostic items are maintained in non-volatile memory (NVRAM), but some
are maintained in read-only memory (ROM).
The table that follows describes the variables.
The first item group in the table includes an example of data to send and to receive. Data
sent from the host to write to NVRAM must contain all digits required by the remote
diagnostic item. All data must be ASCII. The printer returns all ASCII data. It is preceded
by the parameter n to identify the diagnostic item and is followed by a Carriage Return
(0D) to signify the end of the data.

Table of Contents

Related product manuals