EasyManua.ls Logo

NCR 7167 - Appendix A: Specifications; Printing Specifications

NCR 7167
344 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7167 Owner’s Manual Chapter 6: Commands
November 2003
240
Transmission Data Hexadecimal Decimal Amount of Data
Block Code 46H 70 1 byte
Fixed value 31H 49 1 byte
Separator 1FH 31 1 byte
Scanning status Normal: 50H
Abnormal: 70H
Normal: 80
Abnormal: 112
1 byte
Detailed information
(See Table below)
40H – 48H 64 – 72 1 byte
Separator 1FH 31 1 byte
Compression process
(*1)(*2)
30H – 39H 48 – 57 0 – 2 bytes
File transmission format
(*1)
30H – 39H 48 – 57 0 – 2 bytes
Separator 1FH 31 1 byte
Fixed value (*1) 34H, 38H, 30H, 34H
38H, 34H, 38H
52, 56, 48, 52,
56, 52, 56
1 – 7 bytes
NUL 00H 0 1 byte
*1. This type of data is not transmitted if an error has occurred.
*2. This value depends on the value set with Function 50 of FS ( g.
Status Information Hexadecimal Decimal
Normal Not abnormal status 40 64
Abnormal There isn’t any data for the scanned image 41 65
Abnormal Processing stopped due to cover open. 44 68
Abnormal An error occurred in the compression of image data 47 71
Abnormal A check feeding error occurred during the scan of the
check.
48 72