84
Appendix
Error Code Error message Description
346 Green DAD1000 Reset Under Voltage Error ICP system status error
347 Green DAD1000 Offset Under Voltage Error ICP system status error
348 Green DAD1000 Thermal Shutdown Error ICP system status error
349 Blue Satellite Reports Reset ICP system status error
350 Blue Satellite Serial Link Error ICP system status error
351 Blue Satellite Firmware Configuration Error ICP system status error
352 Blue DAD1000 Bias Under Voltage Error ICP system status error
353 Blue DAD1000 Reset Under Voltage Error ICP system status error
354 Blue DAD1000 Offset Under Voltage Error ICP system status error
355 Blue DAD1000 Thermal Shutdown Error ICP system status error
356 RTC Error Indicates that ICP RTC is set to a date before January 1,
2009, and is likely invalid. If the year value is less than
2009, then the time is considered to be “invalid”.
370 ICP Frame Memory Test Result Fail ICP self test error due to “Frame memory error”
372 ICP Data Path Signature Test Result Fail ICP self test error due to “Data Path Signature Test Result
Fail”
400 Enigma Comm Fail No communication with the Enigma board.
410 System Error Enigma Status error
411 Self Test Error Enigma Status error
412 Install Release Package Error Enigma Status error
413 Load Release Package Error Enigma Status error
414 TI Login List Package Error Enigma Status error
415 Security Officer Login List Package Error Enigma Status error
419 Certificate or Key Error Enigma Status error
420 ICP Communications Status Enigma fails to do logical marriage to ICP when Enigma
powers up. Because of no communications with ICP
during logical marriage.
426 User Loader Integrity Error Enigma is in FIPS error state. (Integrity check error)
427 Main Application Integrity Error Enigma is in FIPS error state. (Integrity check error)
428 RNG Hardware Integrity Error Enigma is in FIPS error state. (Integrity check error)
429 DRNG Algorithm Integrity Error Enigma is in FIPS error state. (Integrity check error)
430 RSA Algorithm Integrity Error Enigma is in FIPS error state. (Integrity check error)
431 AES Algorithm Integrity Error Enigma is in FIPS error state. (Integrity check error)
432 HMAC Algorithm Integrity Error Enigma is in FIPS error state. (Integrity check error)
433 SHA Algorithm Integrity Error Enigma is in FIPS error state. (Integrity check error)
434 TLS Integrity Error Enigma is in FIPS error state. (Integrity check error)
435 FPGA Configuration Integrity Error Enigma is in FIPS error state. (Integrity check error)
436 FPGA CineLink 2 Decryption Integrity Error Enigma is in FIPS error state. (Integrity check error)
437 RTC Error Indicates that Enigma RTC is set to a date before January
1, 2009, and is likely invalid. If the year value is less than
2009, then the time is considered to be “invalid”
442 FPGA Configuration Error Enigma Status error
443 FPGA Temperature out of range Enigma Status error
446 RNG Hardware Duplicate Output Error Enigma is in FIPS error state. (Integrity check error)
447 DRNG Algorithm Duplicate Output Error Enigma is in FIPS error state. (Integrity check error)
450 1.20V Supply out of range Enigma Status error
451 1.80V Supply out of range Enigma Status error
452 2.50V Supply out of range Enigma Status error
453 3.30V Regulator out of range Enigma Status error
458 SelfTest User Loader Integrity Error Enigma is in FIPS error state. (Self test result)
459 SelfTest Main Application Integrity Error Enigma is in FIPS error state. (Self test result)
460 SelfTest RNG Hardware Integrity Error Enigma is in FIPS error state. (Self test result)
461 SelfTest DRNG Algorithm Integrity Error Enigma is in FIPS error state. (Self test result)
462 SelfTest RSA Algorithm Integrity Error Enigma is in FIPS error state. (Self test result)
463 SelfTest AES Algorithm Integrity Error Enigma is in FIPS error state. (Self test result)