Program
Number
Program Name Description/Comments Assigned Data 1 2 3
84-24-34 DT800/DT700 Multiline
CODEC Basic Informa-
tion Setup – G.722 Jit-
ter Buffer Minimum
Minimum value of the dynamic jitter
buffer.
Range: 0 ~ 255ms
Default is 30
X
84-24-35 DT800/DT700 Multiline
CODEC Basic Informa-
tion Setup – G.722 Jit-
ter Buffer Average
Average value of the dynamic jitter
buffer.
Range: 0 ~ 255ms
Default is 60
X
84-24-36 DT800/DT700 Multiline
CODEC Basic Informa-
tion Setup – G.722 Jit-
ter Buffer Maximum
Maximum value of the dynamic jitter
buffer.
Range: 0 ~ 255ms
Default is 120
X
84-28-01 DT800/DT700 Multiline
Firmware Name Setup
– Firmware Directory
Maximum 64 characters. Default is No Setting X
84-28-02 DT800/DT700 Multiline
Firmware Name Setup
– Firmware File Name
Maximum 30 characters. Default is No Setting X
13.10 SIP MLT Quick Startup Guide
The following guides describe the setup for a SIP MLT from a default state for these modes:
• Plug and Play
• Automatic Registration
• Manual Registration
13.10.1 Plug and Play
1. Program 10-12
Assign the VoIPDB registration/signaling IP address, subnet mask, and default gateway. If no
customer provided default gateway is provided, leave Gateway IP address at 0.0.0.0.
Figure 9-26 System Data 10-12: CPU Network Setup
ISSUE 1.0
SL2100
Networking Manual 9-37