SYSTEM CONFIGURATION PROCEDURE
7 SYSTEM CONFIGURATION PROCEDURE
Device Delay Configuration, page 35
Pump Station Configuration, page 38
Valve Configuration, page 39
Valve Flow Rate, page 40
Water Meter, page 41
Dosing Channel Configuration, page 42
Dosing Configuration, page 43
Drainage Configuration, page 44
EC/pH Configuration, page 44
Cooling Configuration, page 45
Misting Configuration, page 45
History Resolution, page 45
System Nutrigation™ Check, page 46
7.1 Device Delay Configuration
The Device Delay Configuration screen enables defining the startup and shutdown order of the irrigation process.
On (mm:ss): On is the definition of the startup order. The set times are taken from procedure startup. The
device with the shortest time will be started first and shifted to procedure startup. Therefore it is recommended
that the device that is to be started first be set as 00:00 (automatically changes to --:--).
Off (mm:ss): Off is the definition of the shutdown order of the irrigation process. The set times are taken from
procedure shutdown. The device with the shortest time will be stopped first and shifted to procedure
shutdown. Therefore it is recommended that the device that is to be stopped first be set as 00:00
(automatically changes to --:--).
CONFIGURATION
1. DEVICE DELAY CONFIGURATION
2. PUMP STATION CONFIGURATION
3. VALVE CONFIGURATION
4. VALVE FLOW RATE
5. WATER METER
6. DOSING CHANNEL CONFIGURATION
7. DOSING CONFIGURATION
8. DRAINAGE CONFIGURATION
9. EC/PH CONFIGURATION
10. COOLING CONFIGURATION
11. MISTING CONFIGURATION

Table of Contents