23.4 Alert Identifiers
The description of the alert identifiers (ID) coming from the NW6000 are as follows:
Alert ID
Caption (max 16)
Description
10002
NO TIME
Time not received for 30s
10003
NO POSITION
Position not received for 30s
10004
NO HEADING
Heading not received for 30s
10005
NO VIDEO
VIDEO not received 'timeout' seconds
10006
NO NMEA
NMEA not received for 'timeout' seconds
10007
NO ANALOG
No analog messages received for 30s
10008
NO DIGITAL
No digital messages received for 30s
10009
AUDIO ERROR
Audio problem mic/vhf/michub
10010
Not in use
10011
BCU ERROR
Connection problem with BCU
10012
TRON40 ERROR
Connection problem Storage (Jotron)
10013
HVR04 ERROR
Connection problem HVR04
10014
STORAGE ERROR
Problem mounting SSD on VDR
10015
Not in Use
10016
Not in Use
10017
FLOATFREE ERROR
Float Free storage alert
10018
Not in Use
10019
CONNECTION ERROR
Configured Device never sent data after restart
10020
POWER FAILURE
Power Failure (mains power gone)
10021
AUDIO TEST ERROR
Microphone Test failed
10022
SWITCH ERROR
Error with switch (Not used now)
10023
SBAND ERROR
No reception SBAND LWE video for 'timeout' seconds
10024
XBAND ERROR
No reception XBAND LWE video for 'timeout' seconds
10025
ECDIS ERROR
No reception ECDIS LWE video for 'timeout' seconds
10026
Not in Use
10027
Not in Use
10028
EXTERNAL STORAGE
Storage Failure on external (USB) storage