24
4. BASIC OPERATION
MULTIFUNCTION GENERATOR
b) Restoration of settings during power supply on/off
This applies to switching the power supply on/off at one time for this equipment and other
embedded devices when this equipment is mounted in a rack.
When the power supply is cut off while the equipment power is on, the equipment power
automatically goes on the next time the power supply is reconnected.
Power supply connected
Settings
AAA
LINE
Power on state The power is switched off.
Power supply connected
Setting change
procedure
Settings
BBB
LINE
Power on state
Power supply reconnected
Settings
MMM
LINE
The power is switched on.
(The settings are set to the
contents of setting memory 1.)
Power supply disconnected
LINE
Power supply disconnected
LINE
1
2
1
Power supply reconnected
Settings
MMM
LINE
The power is switched on.
(The settings are set to the
contents of setting memory 1.)
The power is switched off.
2
• The settings before the power is switched off cannot be restored.
• The contents of setting memory number 1 are set. ) p. 122
• The output on/off settings at power-on can be set on the Utility screen. ) p. 41
Check
Since the settings before the power supply is cut off are not restored, specify
the contents of setting memory number 1 beforehand if required. ) p. 122