ENGLISH – 11
4.2 WIRING DIAGRAM AND DESCRIPTION OF CONNECTIONS
4.2.1 Wiring diagram
Wiring diagram with relay photocells without PHOTOTEST
1
2
345
6
78
LR
LK
DISPLAY
LED OK
LS
LED STOP
SbS
PHOTO
12V
STOP
GND
PHOTOTEST
+24V (COMMON)
FLASH
LED
RADIO
FUSE
RX
TX
21 543
1 2
+12V - OSE
NO
NC
OSE
8k2
NO
FLASH
27
4.2.2 Description of connections
Table 3
ELECTRICAL CONNECTIONS
Terminals Description
FLASH
This output is programmable (refer to the “PROGRAMMING” chapter on page 16) to connect one of the
following devices: Warning light, “Door open indicator” output, Suction cup [Note 1], Electric latch [Note 1],
Electric lock [Note 1], Courtesy light, Radio channel no. 1-4
If programmed as “warning light”, on the “FLASH” output it is possible to connect a “ELDC” warning light or
similar with a single 12 V maximum 21 W car-type lamp. During the manoeuvre, check that the warning light
ashes at intervals of 0.5 seconds on and 0.5 seconds off.
If programmed as “door open indicator”, on the “FLASH” output it is possible to connect a 24 V max 10W
indicator light to signal the door open status. It can also be programmed for other functions (refer to the “PROG
RAMMING” chapter on page 16).
If programmed as “suction cup”, on the “FLASH” output it is possible to connect a 24 V max 10 W suction
cup (versions with electromagnet only, without electronic devices). When the door is closed, the suction cup is
activated to lock the door in place. During the opening and closing manoeuvre, it is deactivated.
If programmed as “electric latch”, on the “FLASH” it is possible to connect a 24 V max 10 W electric device
with latch (versions with electromagnet only, without electronic devices).
During the opening manoeuvre, the electric latch is activated and remains active to free the door and perform
the manoeuvre.
During the closing manoeuvre, ensure that the electric latch re-engages mechanically.
If programmed as “electric lock”, on the “FLASH” output it is possible to connect a 24 V max 10 W electric
lock with latch (versions with electromagnet only, without electronic devices).
During the opening manoeuvre, the electric lock is activated for a brief interval to free the door and perform the
manoeuvre. During the closing manoeuvre, ensure that the electric lock re-engages mechanically.