Page #20 background imageLoading...
Page #20 background image
20 – ENGLISH
7.7 SETTING THE PHOTOTEST OPERATION
Function found in the PHOTOTEST CONFIGURATION menu
(OUT2).
This function allows for modifying the operating setting of the PHO-
TOTEST (OUT2) output.
Using the
f
and
h
buttons, select one of the
values present in the underlying table. To conrm it, press the
g
button.
Table 9
PHOTOTEST (OUT2) OUTPUT SETTING
Value Description
(Default)
Phototest
Allows for verifying, at the start of a manoeuvre,
the correct operation of all the safety devices
(see the “Photocells with PHOTOTEST function
paragraph on page 27).
Note: Whenever this setting is chosen, the devices
must be learned again (see “Programming the door
opening and closing positions”).
24 V DC 3 W output
Door status
This function allows for activating the output when the
motor is moving.
Output active 24 V DC / max 3W
Electric lock
When the opening manoeuvre is performed, the electric
lock activates for 3 seconds.
Output active 24 V DC / max 3W
Electric latch
When the opening manoeuvre is performed, the
electric lock activates. It is not active during the closing
manoeuvre.
Output active 24 V DC / max 3W
Suction cup
The suction cup activates when the application is
in the fully closed position; in all other situations it is
deactivated. When the suction cup deactivates, before
an opening manoeuvre starts there is a 3-second delay.
Output active 24 V DC / max 3W
Courtesy light
When the manoeuvre is performed, the output activates
and stays activated for 1 minute after the end of the
manoeuvre.
Output active 24 V DC / max 3W
Radio channel 1
If this radio channel is set, the output activates when a
command is sent with the transmitter.
WARNING! If this radio channel is not free on the control
unit receiver, due to having being previously memorised
with a command, the control unit will only activate the
programmed output when the channel is activated with
the transmitter, ignoring the command towards the
motor.
Output active 24 V DC / max 3 W
Radio channel 2
Like setting no. 6, on radio channel 2.
Radio channel 3
Like setting no. 6, on radio channel 3.
Radio channel 4
Like setting no. 6, on radio channel 4.
7.8 SETTING THE TENSION RELEASE
Function found in the TENSION RELEASE menu.
This function allows for releasing the mechanical tension that ac-
cumulates in the components after every manoeuvre. When the
closing position is reached, the motor will perform a brief inversion
to release the belt or chain tension.
Using the
f
and
h
buttons, select one of the
values present in the underlying table. To conrm it, press the
g
button.
a
At the end of the operation, the automation will ask
to run the automatic force search procedure, sig-
nalling it with the ashing courtesy light (consult
the “Automatic force search” chapter on page 14).
Table 10
TENSION RELEASE SELECTION
Value Description
Release deactivated
Minimum release
...
...
...
(Default)
Medium release
...
...
...
Maximum release

Table of Contents

Other manuals for Nice Spido

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nice Spido and is the answer not in the manual?

Nice Spido Specifications

SP6000

Power IconPower
power input230 Vac ±10%, 50 / 60Hz
flashing light output voltage24 Vac
flashing light output power25 W
Operating Environment IconOperating Environment
operating temperature-20 °C - 70 °C
maximum duration of a manoeuvre60 seconds
courtesy light time60 seconds
Service Supply IconService Supply
service supply output voltage24 Vac
service supply maximum current200 mA
pause timeProgrammable from 5 to 250 seconds

SP6000/V1

Power IconPower
power input120 Vac ±10%, 50 / 60Hz

Related product manuals