28 – ENGLISH
Wiring diagram with relay photocells with PHOTOTEST
1
2
345
6
78
LR
LK
DISPLAY
LED OK
LS
LED STOP
LED
RADIO
FUSE
SbS
PHOTO
12V
STOP
GND
PHOTOTEST
FLASH
RX
TX
21 543
1 2
+12V - OSE
FLASH
NO
NC
OSE
8k2
NO
+24V (COMMON)
54
9.1.3 Electric lock
The PHOTOTEST output is by default enabled for the PHOTOTEST
function, but can be programmed for controlling an electric lock
(see the “Setting the PHOTOTEST operation” chapter on page
20).
At the start of the opening movement, the output is activated for
2 seconds, while during the closing manoeuvre it is not activated,
therefore the electric lock must reset mechanically.
The output cannot control the electric lock directly, but only loads
of 24 V c 3 W.
The output must be interfaced with a relay, as shown in the gure.
1
2
345
6
78
A
C
B
55
A Electric lock
B 24 V c support relay
C Electric lock power supply
9.2 CONNECTING AND INSTALLING THE BACK-
UP BATTERY
f
The electrical connection of the battery to the con-
trol unit must be made only after completing all the
installation and programming stages, as the battery
is an emergency power supply.
To install and connect the battery:
1. loosen the screw (A)
2. pull the cover (B) slightly outwards and turn it downwards
(“Figure 56“)
A
B
56

Table of Contents

Other manuals for Nice Spido

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nice Spido and is the answer not in the manual?

Nice Spido Specifications

SP6000

Power IconPower
power input230 Vac ±10%, 50 / 60Hz
flashing light output voltage24 Vac
flashing light output power25 W
Operating Environment IconOperating Environment
operating temperature-20 °C - 70 °C
maximum duration of a manoeuvre60 seconds
courtesy light time60 seconds
Service Supply IconService Supply
service supply output voltage24 Vac
service supply maximum current200 mA
pause timeProgrammable from 5 to 250 seconds

SP6000/V1

Power IconPower
power input120 Vac ±10%, 50 / 60Hz