18 – ENGLISH
7.3 SETTING OF THE MOTOR FORCE
Function found in the FORCE menu.
This function allows for modifying the force and friction sensitivity
that the control unit uses to move the door.
Using the
f
and
h
buttons, select one of the
values present in the underlying table. To conrm it, press the
g
button.
Table 5
MOTOR FORCE SELECTION
Value Description
Minimum force
...
...
...
...
(Default)
Medium force
...
...
...
Maximum force
7.4 SETTING THE MOTOR SPEED
Function found in the SPEED menu.
This function allows for modifying the automation’s opening and
closing speeds.
Using the
f
and
h
buttons, select one of the
values present in the underlying table. To conrm it, press the
g
button.
a
At the end of the operation, the automation will ask
to run the automatic force search procedure, sig-
nalling it with the ashing courtesy light (consult
the “Automatic force search” chapter on page 14).
Table 6
MOTOR SPEED SELECTION
Value Opening speed Closing speed
Speed 40% Speed 40%
Speed 50% Speed 50%
Speed 50% Speed 75%
Speed 50% Speed 100%
Speed 75% Speed 50%
Speed 75% Speed 75%
Speed 75% Speed 100%
Speed 100% Speed 50%
(Default)
Speed 100% Speed 75%
Speed 100% Speed 100%

Table of Contents

Other manuals for Nice Spido

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nice Spido and is the answer not in the manual?

Nice Spido Specifications

SP6000

Power IconPower
power input230 Vac ±10%, 50 / 60Hz
flashing light output voltage24 Vac
flashing light output power25 W
Operating Environment IconOperating Environment
operating temperature-20 °C - 70 °C
maximum duration of a manoeuvre60 seconds
courtesy light time60 seconds
Service Supply IconService Supply
service supply output voltage24 Vac
service supply maximum current200 mA
pause timeProgrammable from 5 to 250 seconds

SP6000/V1

Power IconPower
power input120 Vac ±10%, 50 / 60Hz