Page #17 background imageLoading...
Page #17 background image
ENGLISH – 17
DISPLAY
OPENCLOSE
45
4. press the
f
or
h
button to modify the de-
sired value
5. press the
g
button to conrm the chosen value and
return to the programming menu or, to exit without making
any change, go to the exit symbol (“Figure 46”) and con-
rm with the
g
button
m
Multiple programming operations can be complet-
ed without exiting the menu: in this case, repeat the
procedure from point 2. At the end of the program-
ming activities, go to point 6.
6. to exit the menu, go to the exit symbol and conrm with the
g
button (“Figure 46“).
DISPLAY
STOP/SET
46
Table 4
PROGRAMMING MENU
Pos. Symbol Values Function Description
- - Control unit awaiting commands
Control unit congured correctly
(programmed devices and acquired
positions)
0
- Access to the menu Visible only upon rst access
1
-
Search for devices and position programming
(see the “Programming the door opening and closing
positions” chapter on page 12)
Allows for learning the connected device
and/or programming the positions
2
0-9
(“Table 5”)
Force
(see the “Setting of the motor force” chapter on page 18)
Allows for modifying the automation’s
opening and closing forces
3
0-9
(“Table 6”)
Speed
(see the “Setting the motor speed” chapter on page 18)
Allows for modifying the automation’s
opening and closing speeds (the “
Automatic force search” will follow)
4
0-9
(“Table 7”)
Automatic closing
(see the “Setting the automatic closing” chapter on page
19)
Allows for activating, deactivating
or modifying the pause time of the
automatic closing cycle
5
0-9
(“Table 8”)
FLASH (OUT1) conguration
(see the “Setting the FLASH function” chapter on page 19)
Allows for modifying the operating setting
of the FLASH (OUT1) output
6
0-9
(“Table 9”)
PHOTOTEST (OUT2) conguration
(see the “Setting the PHOTOTEST operation” chapter on
page 20)
Allows for modifying the operating setting
of the PHOTOTEST (OUT2) output
7
0-9
(“Table 10”)
Tension release
(see the “Setting the tension release” chapter on page 20)
Allows for modifying the tension length
(the “Automatic force search” will
follow)
8
0-3
(“Table 11”)
SbS operation
(see the “Setting the SbS operation” chapter on page 21)
Allows for modifying the operating setting
of the Step by Step command
9
0-3
(“Table 12”)
Memory deletion
(see the “Memory deletion” chapter on page 21)
Allows for deleting the existing
conguration or the memorised radio
remote controls
10
- Exit
Exit from the menu or cancellation of the
current modication of a parameter

Table of Contents

Other manuals for Nice Spido

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nice Spido and is the answer not in the manual?

Nice Spido Specifications

SP6000

Power IconPower
power input230 Vac ±10%, 50 / 60Hz
flashing light output voltage24 Vac
flashing light output power25 W
Operating Environment IconOperating Environment
operating temperature-20 °C - 70 °C
maximum duration of a manoeuvre60 seconds
courtesy light time60 seconds
Service Supply IconService Supply
service supply output voltage24 Vac
service supply maximum current200 mA
pause timeProgrammable from 5 to 250 seconds

SP6000/V1

Power IconPower
power input120 Vac ±10%, 50 / 60Hz

Related product manuals