Adjusting of the trigger contact
Turn off the machine and disconnect the mains cable.
Remove safety cover (2) (Fig. 2, page 11).
Remove the housing screws (31) and take off cover (17) (Fig. 2, page 11).
Tilt the electronic part back
Retract the release rod (41) and loosen the screws (42) of the drive element (43). The drive
element should now be easily movable on the release rod (Fig. 30).
Shift drive element (43) on the release rod (41) forward by
approx. 5 mm (Fig. 31).
Carefully pull the stripping head fully forward by hand.
Fig. 30. Loosen drive ele-
ment
Fig.
31
. Shift drive element