www.nitronic.ch - 50 -
Nitronic AG
Mattenstrasse 11
CH – 2555 Bruegg Tel. +41 32 373 7070
Switzerland Fax +41 32 373 70
75
Fault
Diagnosis
Remedy Action
The stripping head
moves to the strip-
ping diameter and
length end position
and stands still.
Motors oscillate.
Irregular operation
starts after a certain
position has been
reached.
Please check.............
if the electrical wiring in the me-
chanical portion is broken.
the mains voltage selector is
wrong.
mains cable has not been
plugged in correctly.
the potentiometer is defective.
screw connections have not
been firmly tightened.
the flat ribbon cable is defective.
Check soldering points and wiring.
Adjust the mains voltage selector as
needed (page 12).
Plug in the cable properly.
Replace as necessary the potentiome-
ter governing diameter or length.
Tighten connections.
Replace the flat ribbon cable.