E010 10.0 Bus timeout (Telegram timeout/bus off 24 V int. CANbus
• Data transfer is faulty. Check P513.
• Check physical bus connections
• Check bus protocol program process.
• Check bus master.
• Check 24 V supply of internal CAN/CANopen bus.
• Node guarding error (internal CANopen)
• Bus off error (internal CANbus)
10.2 Bus timeout option Telegram timeout
• Telegram transfer is faulty.
• Check physical bus connections
• Check bus protocol program process.
• Check bus master.
• PLC is in the "STOP" or "ERROR" state.
10.4 Init error option Initialization error in bus module
• Check bus module current supply.
• DIP switch setting of a connected I/O extension
module is incorrect
10.1 System error option System error bus module
• Further details can be found in the respective
additional bus instructions.
I/O extension:
Incorrect measurement of the input voltage or undefined
provision of the output voltage due to error in
reference voltage generation.
• Short circuit at analog output
10.3
10.5
10.6
10.7
10.9 Module missing/P120 The module entered in parameter (P120) is not available.