6 Operating status messages
BU 0240 en-US-4920 81
Pos: 665 /A nleit ung en/El ek tr onik /FU und Star ter /6. M eldung en zum B etrie bsz ust and /Stör m eld ung en (A ufli st ung)/ Fehl er E0 07 [ SK 5 00P, S K 18 0E, SK 2 00E (-FDS), SK500E] @ 58\mod_1606137730820_14638.docx @ 2694962 @ @ 1
Fault on supply connection side
• A power phase is not connected
• Line power is asymmetric
• A power phase is not connected
• Load temporarily too high
Pos: 666 /A nleit ung en/El ek tr onik /FU und Star ter /6. M eldung en zum B etrie bsz ust and /Stör m eld ung en (A ufli st ung)/ Fehl er E0 07 - H inwei s [SK 50 0P, SK 200 E(-FDS), SK500E] @ 58\mod_1606138157993_14638.docx @ 2695039 @ @ 1
Devices with external 24 V DC supply of the control
unit:
If the line voltage is switched off, but the control unit is still
supplied with 24 V DC, this error message also occurs.
If the line voltage is switched on again, the error message
must be acknowledged. It is not before until the
variable frequency drive can be released.
Pos: 667 /A nleit ung en/El ek tr onik /FU und Star ter /6. M eldung en zum B etrie bsz ust and /Stör m eld ung en (A ufli st ung)/ Fehl er E0 08 [ SK 2x xE] @ 2\m od_1347453314366_14638.docx @ 46577 @ @ 1
E008 8.0 Parameter loss
(maximum EEPROM value
exceeded)
Error in EEPROM data
• Software version of the stored data set not
compatible with the software version of the VFD.
NOTE: Faulty parameters are automatically reloaded
(default data).
• EMC interferences (see also E020)
8.1 Inverter ID error, “Inverter
type incorrect”
• EEPROM faulty
8.2 Reserved
8.3 EEPROM KSE error
(Customer unit incorrectly
identified (customer's interface
equipment))
The upgrade level of the variable frequency drive was not
correctly identified.
EEPROM with a firmware status of version 1.2 or above
plugged in to an VFD with older firmware status → Loss of
parameters! (also see Information in section 5)
• Switch line voltage off and on again.
8.4 Internal EEPROM error
(Database version incorrect)
8.7 EEPROM copy differs, “EEPR
copy not the same”
Pos: 668 /A nleit ung en/El ek tr onik /FU und Star ter /6. M eldung en zum B etrie bsz ust and /Stör m eld ung en (A ufli st ung)/ Fehl er E0 09 "r es ervier t" [ SK 180E/ SK 2x xE/ SK2x xE-FD S] @ 2\mod_1347453797027_14638.docx @ 46702 @ @ 1
E009 --- Reserved
Pos: 66 9 /Allg emein/ Allg emeing ültig e Mod ule/---------Sei tenum bruc h k omp akt --------- @ 13\mod_1476369695906_0.docx @ 2265496 @ @ 1