7 Fault elimination
7.1 Fault indication
Malfunctions during operation are indicated by a corresponding Warning
or Error message in the display of the control unit:
Warning messages
The control of the Nordmann AT4 checks whether there is a temporary
problem (e.g. water supply interrupted for a short time) or whether it
can resolve the problem by taking necessary measures. If the cause of
the malfunction disappears of its own accord or if the control can repair
the malfunction, the alarm message will automatically switch off. If the
cause of the malfunction does not disappear even after a longer period
of time, a error message is triggered.
Error message (additionally to the error message the red LED lights)
Further operation is normally not possible any longer, the unit is blocked.
To eliminate the malfunction see chapter 7.1 and 7.3.
Note: After eliminating the malfunction the error message must be reset
(see chapter 7.4).
By pressing the <Info> key additional information can be displayed for each
warning and/or error message.
Note: if you want to see further information of an active warning or error
message of a humidier on the optional remote terminal, select “Excep
tion” in the diagnostic menu of the appropriate steam humidier (appears
only on the remote terminal), then press <Set> key:
Menu Info
Warning
W21 Cyl.Max.Level
Menu Info
Error
E33 Lim Sens broken
Esc
Error 33
Lim Sens broken
No sensor signal
humidity sensor def.
Main Menu
Engineering :Set
Diagnostic :Set
User :Set
Esc Set
Diagnostic
ErrorHistory:Set
Unit Status :Set
Remote Test :Set
Exception :Set
Modul-B Test:Set
Esc Set
Menu 1
AT4 130kg/h 400V3
Standby
2011-08-31 12.00.00
Esc
Error 33
Lim Sens broken
No sensor signal
humidity sensor def.