PICO Toµch Controller
54 www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.
Appendix A, Remotely Operating the Controller
(continued)
Valve (Driver)
Command Description Command Format
Sample, with Output
After [Enter]
drv1 Sets the valve mode
(MODE)
x=1–5
Where x equals:
1drv1 Sets MODE to Timed
2drv1 Sets MODE to Purge
3drv1 Sets MODE to Continuous
5drv1 Reads the current mode
1drv1
[Enter]
Driver 1: TIME
2drv1
[Enter]
Driver 1: PURG
3drv1
[Enter]
Driver 1: CONT
5drv1
[Enter]
Driver 1: CONT
dcn1 Sets the valve dispense
count (COUNT)
xxxxxdcn1
Where x = > 00001–65535 counts (DCNT)
00001dcn1
[Enter]
Dispense Count (DCNT) = 00001
ont1 Sets the valve ON time
(PULSE)
xxxx.xxont1
Where xxxx.xx = ON time in ms
NOTE: Time is entered as an ON / OFF time
where ON = PULSE and Cycle = ON + OFF. ON
and OFF times should be adjusted together to
preserve the Cycle time setting.
0001.45ont1
[Enter]
Time Set To = 0001.45 ms
oft1 Sets the valve OFF time
(CYCLE)
(Where OFF time + ON
Time = CYCLE)
xxxx.xxoft1
Where xxxx.xx = OFF time in ms
NOTE: Time is entered as an ON / OFF time
where ON = PULSE and Cycle = ON + OFF. ON
and OFF times should be adjusted together to
preserve the Cycle time setting.
0005.00oft1
[Enter]
Time Set To = 0005.00 ms
rdr1 Returns the valve status rdr1 rdr1
[Enter]
MODE: TIME
PULSE: 0001.45ms
CYCLE: 0006.45ms
COUNT: 00002
Prole Rise.: 1
Prole Fall.: 1
Stroke: 0045
Up Ramp Time: 000.250ms
Dwn Ramp Time: 000.250ms
Close Voltage: 100
Num Shots: 0015731319
Power Mode: Default
Continued on next page