Nordson iControl - System Specifications Summary

Nordson iControl
189 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Overview
2-7
Part 1105779-04
E 2014 Nordson Corporation
Specifications
General
Air Pressures
Input 6.27.6 bar (90110 psi)
Supply air hose
3
/
4-
in. ID minimum
Maximum output per pump 13.6 m
3
/hr (8 scfm)
Maximum output per channel (flow-rate,
atomizing)
6.8 m
3
/hr (4 scfm)
Gun air (electrode wash) 0.36 m
3
/hr (0.2 scfm)
Electrical Requirements
Input
Unswitched: (PC) 100230 Vac, 50/60 Hz, 1 , 120 VA max.
Switched: 100230 Vac, 50/60 Hz, 1 , 600VA max.
Conveyor Interlock and Remote Lockout: 120/230 Vac, 50/60
Hz, 1 , 6 mA
Alarm Relay contact rating: 120/230 Vac, 1 , 6 A
Output (to spray gun) 021 Vdc, 0.60 A
NOTE: The iControl system must be interlocked with the fire detection system so that the spray guns are
shut off if a fire is detected inside the spray booth.
ANSI/ISA S82.02.01
Pollution Degree 2
Installation (Overvoltage) Category II
Environmental
Operating Temperature
32104 _F (040 _C)
Operating Humidity 595%, non-condensing
Hazardous Location Rating
North America: Class II Division 2, Groups F & G