Installation
3-5
Part 1105779-04
E 2014 Nordson Corporation
iControl Console Power Cable Connections
Table 3-2 Master and Slave Console Power Cable Connections
Master Console Power Cable Connections (A)
Wire Color Connection Function
Black L1 (hot)
100−240 Vac power to SBC (master console only) (unswitched)
White L2 (neutral)
Brown L1 (hot)
120−240 Vac power to console power supply (master and slave consoles)
(switched with booth exhaust fan motor)
Blue L2 (neutral)
Green/Yellow Chassis Ground (master and slave consoles)
Gray (2) Remote Lockout: 240 Vac, 1 phase, 6 mA (for 120 Vac, refer to instructions below)
Yellow (2) Alarm contacts: 120/230 Vac, 1 phase, 6 A max. Closed with no power to console or
alarm is present. Open with power applied to console and no alarms present.
Red, Orange Conveyor Interlock: 240 Vac, 1 phase, 6 mA (for 120 Vac, refer to instructions below)
Slave Console Power Cable Connections (B)
Wire Color Connection
Blue L1
Brown L2
Green/Yellow GND