Installation
3-14
Part 1105779-04
E 2014 Nordson Corporation
Maximum Emitter/Receiver Separation:
6 meters (20 ft) if scanner is less than 1.22 meters (4 ft) long
4.6 meters (15 ft) if scanner is greater than 1.22 meters (4 ft) long.
NOTE: If using a single horizontal scanner, the controller must be
programmed to ignore the conveyor. This requires software from the
scanner manufacturer, a laptop running Windows, and a serial cable to
connect the laptop to the scanner controller in the junction box.
BSCE−L
BSCR−L
BSCE−R
BSCR−R
Dual Positioner Scanner Configuration
PEJB
Positioner
Scanner J-Box
SCNR1
SCNR1
Ethernet
BSCE
BSCR
PEJB
Positioner
Scanner J-Box
SCNR1
SCNR1
Ethernet
Single Positioner Scanner Configuration
Figure 3-8 System Wiring − In/Out Positioner Scanner Connections
Customer-Supplied Part ID System Connections
Refer to Table 3-3 on page 3-10. Use the Part ID terminals on the Photoeye
Junction Box to connect a customer-supplied part ID system to the iControl
console. The 8 inputs are used based on the settings made in the
Photoeye Configuration screen. Refer to the iControl Operator Interface
manual for configuration instructions.