Troubleshooting
4-28
Part 1105779-04
E 2014 Nordson Corporation
CorrectionMessageError
Code
2107 Speed calculated less than
minimum
Default or preset settings for variable mode resulting in speed
less than minimum.
Minimum speed is 15 ft/min. Change default or preset
settings. Part may be too small to use variable mode, change
to a fixed mode.
2108 Speed calculated greater
than maximum
Default or preset settings for variable mode or fixed with
conveyor synchronization resulting in speed faster than
maximum.
Change the default or preset settings or reduce the conveyor
speed.
1112 Positioner not in ready state
for color change
In/out positioner not in Manual or Auto mode.
Color change cycle cannot start unless in/out positioner is in
Manual or Auto mode. Set in/out positioner mode to Manual
or Auto.
2113 Reciprocator not in ready
state for color change
Reciprocator not in Auto mode.
Color change cycle cannot start unless reciprocator is in Auto
mode. Set reciprocator mode to Auto.
3200 Reciprocator Watchdog fault The reciprocator controller did not respond with a watchdog
signal in 1 second.
Check the Ethernet cable connections and the reciprocator
controller.
Other Reciprocator Troubleshooting
Table 4-10 Other Reciprocator Troubleshooting
Problem Cause Correction
No movement from
reciprocator in
response to move
command
A fault has occurred
preventing operation.
Check the iControl alarm log.
Identify the fault and review the fault
troubleshooting information in this table.
Controller configuration
jumpers not in place.
Refer to in/out positioner/reciprocator control
panel drawings in Section 7 for function
identification and jumper placement
instructions.
Configuration lockout applied
to reciprocator.
Check the Reciprocator control screen for the
lockout indicator. Lockout is applied from the
Configuration screens.
iControl lockout applied to
guns, in/out positioners, and
reciprocators.
This is a normal condition unless a failure has
occurred. Refer to Photoeye, Encoder, and
Interlock Troubleshooting in this section.
Continued...