Installation
3-4
Part 1105779-04
E 2014 Nordson Corporation
Table 3-1 Flow Module SW4 Dipswitch Settings
Gun Air Console Address
SW4−1
(Gun A)
SW4−2
(Gun B)
Air Flow SW4−3 SW4− 4 Console
Down Down Continuous Up Up 1 (master)
Up Up Trigger Up Down 2 (slave)
123
UP
4
Gun Air
Flow
Console
Address
Set to Flow Module
Number (1−8)
Module Arrangement
(Inside Door)
1 2
3 4
5 6
7 8
SW4
SW3
Figure 3-3 iFlow Module Address
Power, Ground, and Relay Connections
The console and junction box power cable ground wires must always be
connected to a true earth ground. The special flat braided ESD ground
cables provided with the iControl consoles and manual gun controllers must
be used to connect them to the booth base if possible. Refer to Grounding
on page 3-7 for more information.
WARNING: Consoles and all conductive equipment in the spray area
MUST be connected to a true earth ground. Use the provided ground
cables to ground the consoles. Mount the junction boxes and control panels
to grounded stands or the booth base. Failure to observe this caution could
result in severe shocks to personnel, fire, or explosion.
Table 3-2 lists the connections required for console power, chassis ground,
remote lockout, alarm contacts, and conveyor interlock. Refer to page 3-11
for optional junction box and control panel power requirements.
Refer to Section 7 for the system diagram, console wiring diagrams, and
junction box and control panel drawings. Refer to your system electrical
drawings for all other power and ground connections.