Installation
3-19
Part 1105779-04
E 2014 Nordson Corporation
Ethernet Termination Standards
Either T568-B or T568-A cables will work in the iControl system. Use the
wiring diagrams in Figure 3-11 when terminating Ethernet cables. Make
sure each end of the cable is terminated using the same type of plug and
wiring arrangement.
Type T568-B Wiring Diagram
Pin Color
1 Orange/White
2 Orange
3 Green/White
4 Blue
5 Blue/White
6 Green
7 Brown/White
8 Brown
Pin Color
1 Green/White
2 Green
3 Orange/White
4 Blue
5 Blue/White
6 Orange
7 Brown/White
8 Brown
Type T568-A Wiring Diagram
Figure 3-11 Ethernet Termination Standards