Other In/Out Positioner Troubleshooting
Table 4-8 Other In/Out Positioner Troubleshooting
Problem Cause Correction
No movement from
in/out positioner in
response to move
command
A fault has occurred
preventing operation.
Check the iControl alarm log.
Identify the fault and review the fault
troubleshooting information in this table.
Controller configuration
jumpers not in place.
Refer to in/out positioner or in/out
positioner/reciprocator control panel drawings
in Section 7 for function identification and
jumper placement instructions.
Configuration lockout applied
to in/out positioner.
Check the In/Out Positioner control screen for
the lockout indicator. Lockout is applied from
the Configuration screens.
iControl lockout applied to
guns, in/out positioners, and
reciprocators.
This is a normal condition unless a failure has
occurred. Refer to Photoeye, Encoder, and
Interlock Troubleshooting in this section.
Remote disable applied to
in/out positioner controller.
No status display on iControl
screens.
If Nordson USA ColorMax system:
Disable action is applied by a remote system
control panel keyswitch. In the Disable
position, the keyswitch opens the disable
input circuit at the in/out positioner controller.
No corrective action is required unless the
keyswitch Normal position does not allow
motion. Refer to your system drawings for
circuit details.
If not Nordson USA ColorMax system:
Apply jumper to force On the remote disable
input. Refer to system drawings for jumper
application.
No in/out positioner
response when Auto
mode selected
A fault has occurred
preventing Auto operation.
Check iControl alarm screen.
Identify the fault and correct. Review the
related faults and corrections listed in this
table.
iControl in/out positioner
configuration settings have
not been completed.
Refer to Network Configuration and In/Out
Positioner Configuration in the iControl
Operator Interface manual. Make sure all
required settings have been made and are
correct.
Refer to the in/out positioner/reciprocator
control panel drawings and make sure all
connections have been made correctly.
Continued...