Troubleshooting
4-1
Part 1105779-04
E 2014 Nordson Corporation
Section 4
Troubleshooting
WARNING: Allow only qualified personnel to perform the following tasks.
Follow the safety instructions in this document and all other related
documentation.
CAUTION: Do not turn off console power without first performing a program
shutdown. Doing so could corrupt the iControl program and operating
system on the program card. Refer to Program Shutdown in the
Configuration section of the iControl Operator Interface manual for the
shutdown procedure.
NOTE: If the troubleshooting procedures in this section do not solve your
problem, contact the Nordson Finishing Customer Support Center at (800)
4339319 or your local Nordson representative.
Error Codes and Alarm Messages
Table 4-1 Error Codes and Messages
Code Message Text Description Refer to
Page
NA = Not currently applicable
* Code may differ on early software releases
10x CAN and Node State
101 CAN bus fault detected N/A 4-7
102 CAN receive buffer overflow Host CAN interface receive too much data
and could not process it quickly enough
4-7
103 Message timeout Remote CAN device did not respond to a
direct response in the allotted time.
4-7
104 Went offline Remote CAN device is no longer online 4-7
105 Returned to online Remote CAN device returned to service 4-7
106 Communication error Host CAN interface detected a communication
error
107 BUSOFF 255 bad CAN messages received
108 Warning Limit exceeded 127 bad CAN messages received
109 Bit error Dominant bit not detected in 5 data bits
110 Form error Fixed format data field contains illegal bits
111 Stuffing error Recessive bit not detected in 5 data bits
Continued...