Troubleshooting
4-2
Part 1105779-04
E 2014 Nordson Corporation
Refer to
Page
DescriptionMessage TextCode
112 Other error Other errors not listed as Bit, Stuff, or Form
113 CAN Transmit Buffer
overflow
Host CAN interface did not transmit data
quickly enough
20x Application
201 Conveyor input not detected Not implemented, future release
202 Encoder not detected Not implemented, future release
203 Zone photoeye stuck on Not implemented, future release
204 Flag photoeye stuck on Not implemented, future release
205 Application setup Not implemented, future release
206 System in lockout Not implemented, future release
30x Electrostatic Controller (Gun Card)
301 Micro−Amp fault detected Microamp value out of range. 4-8
302 Foldback fault detected Current foldback detected. 4-8
303 Feedback fault detected Microamp feedback detected. 4-8
304 Open circuit detected No multiplier load detected. 4-8
305 Short circuit detected Multiplier drive circuit shorted. 4-8
306 Internal hardware fault
detected
Internal DSP fault. 4-9
307 Tribo Tribomatic gun current feedback low. 4-9
308 Gun not detected Gun not connected to system. 4-9
40x iFlow Controller
401 Flow valve not detected or
bad
The solenoid resistance was not detected or
incorrect when the device was not triggered.
4-13
402 Atomize valve not detected
or bad
The solenoid resistance was not detected or
incorrect when the device was not triggered.
4-13
403 Auxiliary solenoid not
detected or bad
The solenoid resistance was not detected or
incorrect when the device was not triggered.
4-13
404 Flow air flow low Air flow less than commanded value. 4-13
405 Atomize air flow low Air flow less than commanded value. 4-13
406 Flow air flow hi Air flow more than commanded value. 4-14
407 Atomize air flow hi Air flow more than commanded value. 4-14
Continued...