Troubleshooting
4-3
Part 1105779-04
E 2014 Nordson Corporation
Refer to
Page
DescriptionMessage TextCode
5xx Remote Device Node
Electrostatic Node (Gun Card)
531 System Heartbeat lost Remote device lost heartbeat message. 4-9
532 5/24 Volt power Remote device power detection failure. 4-9
533 Error writing to internal
EEPROM
Error saving data to remote device onboard
EEPROM.
4-9
534 Error reading from internal
EEPROM
Error reading data from remote device
onboard EEPROM.
4-9
535 Node address changed from
last powerup
The saved address does not match the
current address for the remote device.
Sending a reset command will clear this state.
4-9
536 Internal database version
changed − resetting to
defaults
An update to the database was detected and
the current data is no longer valid.
4-9
537 Preset out of range The preset sent to the remote device was out
of range.
4-9
538 Trigger ON message
received − controller in
lockout
Remote device was commanded to trigger
while in lockout.
4-9
iFlow Node
541 System Heartbeat lost Remote device lost heartbeat message. 4-14
542 5/24 Volt power Remote device power detection failure. 4-14
543 Error writing to internal
EEPROM
Error saving data to remote device onboard
EEPROM.
4-14
544 Error reading from internal
EEPROM
Error reading data from remote device
onboard EEPROM.
4-14
545 Node address changed from
last powerup
The saved address does not match the
current address for the remote device.
Sending a reset command will clear this state.
4-14
546 Internal database version
changed − resetting to
defaults
An update to the database was detected and
the current data is no longer valid.
4-14
547 Preset out of range The preset sent to the remote device was out
of range.
4-14
548 Trigger ON message
received − controller in
lockout
Remote device was commanded to trigger
while in lockout.
4-14
Continued...