Installation
3-13
Part 1105779-04
E 2014 Nordson Corporation
Single Zone Scanner
Dual Zone Scanners
Part ID and Zone Scanners
SCNR1
SCNR1
SCNR2
PEJB
Part ID Scanner
Zone Scanner
Part Travel
Figure 3-7 Zone and Part ID Scanner Cable Connections (Typical)
Analog Scanner Connections
See Figure 3-8. If the system includes in/out positioners, then one or two
analog scanners are mounted horizontally on the stand to detect the part
width. The in/out positioner scanner junction box is typically located on the
light stand. The scanners must be mounted with the cable ends oriented as
shown. If using dual scanners, mount them so that they do not see the
conveyor. Connect the scanner cables (BSCE, BSCR) from the junction
box to the scanners as shown.
If the system also has reciprocators, then analog scanners are used to
detect the part height and top and bottom edges. Mount the scanners with
the cable ends down and connect the cables (SCNR1) from the junction box
to the scanners.