Overview
2-8
Part 1105779-04
E 2014 Nordson Corporation
Air Quality
Air must be clean and dry. Use a regenerative desiccant or refrigerated air
dryer capable of producing a 3.4 _C (38 _F) or lower dew point at 7 bar
(100 psi) and a filter system with pre-filters and coalescent type filters
capable of removing oil, water and dirt in the submicron range.
Recommended Air Filter Screen Size: 5 micron or smaller
Maximum Oil Vapor in Air Supply: 0.1 ppm
Maximum Water Vapor in Air Supply: 0.48 grains/ft
3
Moist or contaminated air can cause the iFlow modules to malfunction; the
powder to cake in the feed hopper, or clog the pump venturi throats, feed
hoses, and spray gun powder paths; and cause grounding or arcing inside
the spray gun.
Special Conditions for Safe Use
S Caution should be taken when cleaning plastic surfaces of the iControl.
There is a potential for static electricity build up on these components.
S The equipment is intended to be used in the ambient temperature from
0_C to 40_C.
Approvals
FM Approved for US and Canada.
Rated for Class II Division 2, Groups F & G Hazardous Location Area
(North America), or Normal Usage Area.