25-Conductor Cable Connections
Table 3-3 Parallel Cable Connections: I/O Board to Junction Box Terminals
(Inputs to I/O Board are Sinking)
Wire Color
I/O Board
Terminal
Junction Box
Terminal Number
Function
BLK 8 LO 1 Zone 1
WHT 9 LO 2 Zone 2
GRN 10 LO 3 Zone 3
ORG 11 LO 4 Zone 4
BLU 12 LO 5 Zone 5
WHT/BLK 13 LO 6 Zone 6
RED/BLK 14 LO 7 Zone 7
GRN/BLK 15 LO 8 Zone 8
ORG/BLK 20 LO 9 Part ID bit 1
BLU/BLK 21 LO 10 Part ID bit 2
BLK/WHT 22 LO 11 Part ID bit 3
RED/WHT 23 LO 12 Part ID bit 4
GRN/WHT 0 LO 13 Part ID bit 5
BLU/WHT 1 LO 14 Part ID bit 6
BLK/RED 2 LO 15 Part ID bit 7
WHT/RED 3 LO 16 Part ID bit 8
ORG/RED 4 LO Trigger Bank 0
BLU/RED 5 LO Trigger Bank 1
RED/GRN 6 LO Trigger Bank
Select Enable
ORG/GRN 7 LO 20 Encoder A
BLK/WHT/RED 16 LO spare
WHT/BLK/RED 17 LO spare
RED/BLK/WHT 18 LO Manual
Lockout
GRN/BLK/WHT N/C
BLUE from
Front Panel
19 HI Not Applicable Conveyor
Interlock
WHITE from
Front Panel
19 LO Not Applicable Conveyor
Interlock
RED 8 HI (+) VDC