Installation
3-26
Part 1105779-04
E 2014 Nordson Corporation
NOTE: Modules must be installed from top to bottom and left to right.
5. Connect the new modules together with new CAN network harnesses.
Refer to the iControl Wiring and Pneumatic Diagrams for harness
requirements and connections.
6. Disconnect the network termination harness from the last old module
and connect it to the last new module.
7. If installing a new regulator, install it on the next available mounting
bracket from the top on the right inside wall.
8. Use 12-mm tubing to connect the regulator to an unused fitting on the
air supply manifold, mounted on the rear wall near the bottom of the
console.
9. Connect the iFlow modules to the regulator with 10-mm tubing.
10. Set the iFlow module network addresses as described on page 3-3.
11. Install the new gun control cards in the card cage, starting with the first
open slot. Cards are installed from left to right.
12. Install the gun control harness receptacles in the rear panel, starting
with the first unused knockout in the row of existing gun control harness
receptacles. Plug the harnesses into the gun control card receptacles.
Use the existing harness installations as a guide.
13. Connect the spray gun cables to the new harness receptacles as
described on page 3-20. If you are using Versa-Spray or Tribomatic
guns you must install an adapter cable between the receptacles and the
gun cables. Refer to Parts for adapter cable part numbers.
14. Connect 8-mm blue and black air tubing from the flow module flow-rate
and atomizing air fittings to the new powder pumps as described on
page 3-21.
15. If used, connect clear 4-mm air tubing from the flow module gun air
fittings to the new spray guns as described on page 3-21.
16. If you installed a new regulator, you must calibrate it for the correct
pressure output. Use an iFlow air flow verification kit and follow the
instructions in the kit instruction sheet. Refer to Miscellaneous Kits in
Parts for the kit part number.
NOTE: If your instruction sheet does not contain the calibration
instructions you can download a new version of the sheet (1039518B or
above) from http://emanuals.nordson.com/finishing, Powder-US>Booths
and Systems>Booth and Trigger Controls, or contact the Nordson
Finishing Customer Support Center or your local Nordson representative
for instructions.
17. Turn on the console and configure the iControl program to add the new
guns to the system. Refer to Gun Configuration in the iControl Operator
Interface manual.
18. Set pickoff points for the new guns as described in the Configuration
section of the iControl Operator Interface manual.
19. Set up presets for the new guns as described in the Preset Setup
section of the iControl Operator Interface manual.