Using the Menus
5-26
Part 1124631_01
E 2015 Nordson Corporation
Tools Menu Screens (contd)
Item Menus Action
Message
Log
4
b
a
c
d
e
f
aTaptheMessage Log button to
view system events.
The Message Log can also be
accessed by tapping the
Diagnostic button in the Status
Bar.
b Message status indicators:
: Active Fault
:InactiveFault
: Active Alert
:InactiveAlert
c Shortcut button:
Depending on the type of alert or
fault, the short cut buttons assist
in resolving the problem.
d Acknowledge button:
Acknowledge stops the flashing
of the screen background (yellow
orred).Forsomefaultsoralerts,
acknowledge may also clear
(make inactive) the fault or alert
condition.
e Message section has three
parts:
S Fault/Alert Name
S Fault/Alert Description
S Troubleshooting tips
f Diagnostic Status/Message
Log button