Troubleshooting
6-7
Part 1124631_01
E 2015 Nordson Corporation
Resolving Alerts and Faults
When a fault or alert condition occurs, the screen background color flashes
red or yellow until the message has been acknowledged.
Tap the button (item 6 in Figure 6-2:) on the Message Log screen to
acknowledge the message. After the alert or fault has been acknowledged,
the background stops flashing. Depending on the type of fault or alert,
holding the acknowledge button may also clear the fault or alert condition,
sending it to the inactive section of the log.
If the fault or ale rt condition continues after the message has been
acknowledged, further steps must be taken to resolve the problem. Use the
troubleshooting tips in the message log as a guide.
Shortcut Buttons
See item 7 in Figure 6-2: for the location of the shortcut button. Depending on
the type of events that occur, one of the following button appears on
Message Log screen:
Button Event
Purge
Applicator
Machine Settings
Self Test
Components
Archive
These buttons provide menu shortcuts that are related to the message. The
messages provide corrective actions.